Where and what in biplanar CT reconstruction: the LiftXR method separates geometry and intensity
LiftXR's new approach reconstructs CT volume from two X-ray projections by first determining the three-dimensional location of anatomical regions and then refining their intensities. On open datasets, the method outperforms previous solutions and improves the quality of downstream segmentation.

An X-ray image is a shadow cast by the body: the detector records how much radiation passes through the tissues. Each point on the image sums up the attenuation along the entire ray, so depth information is irretrievably lost. If you take just two images—from different angles—the problem still remains underdetermined: there are infinitely many three-dimensional density distributions that will produce identical projections. Classical methods solve this problem through regularization and prior assumptions, but often pay the price with blurred boundaries and artifacts.
This is exactly where LiftXR comes in—a new approach that proposes breaking down the complex problem into two simpler ones: determining where anatomical structures are located in space and what they are in terms of intensity. Instead of searching for a single volumetric field, the method first builds a rough geometric map and then refines it against the X-ray data.

Why depth is not enough
To understand the problem, it is worth recalling the physics: a ray is attenuated proportionally to the density of tissues along its path. The resulting signal is an integral from which the integrand cannot be recovered without additional conditions. Biplanar imaging adds a second view from a different angle, but even a pair of projections does not allow an unambiguous 3D reconstruction. Mathematically, the problem belongs to the class of ill-posed problems: small errors at the input lead to large deviations in the solution, and many different volumes produce the same set of projections. Therefore, additional constraints or hints are needed.
Where and what: two questions of reconstruction
The key idea behind LiftXR is to separate the "where" and "what" questions. The first question concerns the spatial arrangement of organs: where are the lungs, bones, and soft tissues? The second concerns what attenuation values correspond to them—that is, how dense a given region is. If both tasks are solved simultaneously, they interfere, and the algorithm may mix geometric errors with intensity errors. If, instead, an anatomical "skeleton"—a rough three-dimensional map of structure locations—is built first, the subsequent intensity recovery gains a reference point.
How it works
The LiftXR method is built on a combination of three modules. The first—layout lifter—generates a 3D anatomy map from a pair of X-ray images. This map defines the spatial boundaries of regions but does not contain precise intensity values. The second module—intensity renderer—takes this map as a condition and recovers a full CT volume, filling each region with appropriate attenuation values. The third module—anatomical parser—works with the finished volume: it analyzes boundaries and intensity signals, refines the initial layout, and feeds this refined version back to correct the intensity-filling process. This feedback loop allows geometric information and intensity data to adjust to each other.

Experiments and results
The authors tested the method on two public datasets. Comparison with recent reconstruction approaches shows that LiftXR produces more accurate CT images according to standard metrics. But most importantly, the reconstructed volumes are better suited for subsequent automatic organ segmentation—that is, they contain fewer anatomical distortions. This means that separating geometry and intensity yields not just visually appealing images, but genuinely improves clinically significant tasks.
Conclusion
In summary, LiftXR demonstrates that decomposing the problem into spatial structure and intensity is a promising path for reconstruction from a limited number of projections. This approach reduces ambiguity and makes it possible to obtain tomograms suitable for further analysis. The authors plan to release the code, which should simplify reproduction and further experiments.
Frequently asked questions
Related materials
All materials
Validating Candidates Costs More Than Generating Them: Honeypots Against LLM Vulnerability Hunting
The study examines the cost asymmetry in agentic vulnerability discovery: generating candidate versions is cheap, while confirming them through reachability analysis, execution, and PoC development consumes most of the budget, making verification a potential standalone target for defense. The proposed RedHerring—repository-adapted decoys with a hidden certificate—reduced the number of real vulnerabilities found by 38.7–60.4% at equal cost across 33 OSS-Fuzz projects; even after the agent was warned, the reduction remained at 37.2%.
9 November 2026
Checking LLM Hallucinations via SQL-Based Source Representation Without Fine-Tuning
The study examines whether an LLM can apply a basic symbolic skill—building a SQL database from source documents—to ground its outputs in sources without supervision when detecting hallucinations. On RAGTruth and DiaHalu, this neuro-symbolic pipeline proves more accurate than direct prediction and comparable to state-of-the-art methods, without requiring domain-specific fine-tuning.
9 November 2026
MathAdv: What the Final Accuracy of Machine-Generated Proofs Conceals
A diagnostic suite of tasks spanning 13 undergraduate and graduate mathematics topics evaluates machine-proving systems in Lean 4 not only by their final results, but also by their subject-matter mastery, the quality of their informal reasoning, and their robustness to rephrased conditions. A component-by-component analysis shows that translating a problem into formal form remains the main obstacle, and that success depends heavily on the area of mathematics and how the problem is framed.
9 November 2026